Bachelor of Science in Radiologic Technology

Radiologic Technology Logo

BS in Radiologic Technology in the Philippines

Bachelor of Science in Radiologic Technology (BSRadTech) is a four year degree program designed to train students how to operate medical imaging equipment such as X-rays, CT scanners, MRIs, sonogram machines, and 3D medical imaging programs among other computer and web-based software programs. Students are also taught how to perform associated clerical duties, including scheduling and maintaining paperwork for office and clinical machinery.

  


 

 The College of Radiologic Technology of DMMC-Institute of Health Sciences , a Commission of Higher Education (CHED) accredited institution aims to be a source of locally and globally competent Radiologic Technologists with expertise in providing high level of skills in the field of Imaging Science.

 

DMMC Institute of Health Sciences proudly announces its latest acquisition of XRAY / Radiographic Positioning Doll.

 

X-Ray Positioning Manikin for Training Radiographers

 

The X-Ray Positioning Manikin is an invaluable teaching aid for training Radiographers in Schools of Radiography, without bringing discomfort or danger to patients or students.

 

This simulator is highly regarded by Schools of Radiography throughout the world

Life-size human figure containing a fully flexible articulated skeleton produced from a specially selected grade of plastic

 No metal parts are used in the articulation of the skeleton

 Easily identifiable anatomical landmarks

 The body covering has the combined properties of being able to simulate surface anatomy whilst remaining totally radiolucent

 Representations of the larynx, heart, lungs and kidneys are constructed from radiolucent material Weight – the Doll is light enough to be carried easily

 Joint flexibility – there is slight hyperflexion of the knees and elbows. The hip rotation is sufficient and generally the joints are realistic

 Flexible and durable articulation of the skeleton ensures a lengthy period of use

 
Positioning

 

The Doll is best used in the recumbent positions as, although it is possible to use an upright bucky with supports, this makes the use of positioning blocks and immobilization devices more difficult. The Doll will lie naturally in the neutral position, prone or supine, without support. A wide selection of positioning aids must be at hand, e.g. foam blocks, wedges, sand bags and compression band. These are essential to maintain any position other than neutral as the skin of the Doll has some resistance to overcome. This is, of course, an advantage in the teaching as it prevents the student cutting corners by omitting the use of these positioning aids. The Doll can be positioned for all standard projections with no more difficulty than a difficult patient might present.

 
Computed Tomography

 

The Radiographic Positioning Doll was positioned and imaged for a whole body CT investigation, making normal use of projection radiography for planning purposes. The resulting images were very good in terms of body outline and fundamental structure, but there were fundamental differences regarding the quantitation of tissue (i.e. the expected CT numbers). Certain areas of the skeletal structure, such as thoracic vertebrae and the head of the femur gave similar values to the typical patient. It was not surprising also that the lung fields were reasonably representative, though lacking in any structure. The Doll fulfills its function very well as a training device for positioning for conventional X-ray and CT. This is because the results of positioning can be imaged (albeit using very unrepresentative exposure factors) and hence the positioning can be critically examined. However, the current design is so different from the human body in terms of X-ray attenuation that it is clearly impossible to use it for training or practicing exposure control.

 

 



Board Exam Records

Year 2015

Passing Rate= 60%                                                                                                                                          National Passing Rate = 43.54% : 16.46% higher than National Passing Rate

 

 

Year 2014

Passing Rate= 80%                                                                                                                                          National Passing Rate = 58.81% : 21.19% higher than National Passing Rate

 

Year 2011:

Passing Rate= 75%
National Passing Rate = 67% :  8% higher than National Passing Rate

Year 2010:

Passing Rate = 100%
National Passing Rate = 51% :  49% higher than national passing rate